製品# | 品目 |
---|---|
DM-001 | Anti-Rabbit Detection Module for Jess, Wes, Peggy Sue or Sally Sue Use with a Jess/Wes or Sally Sue/Peggy Sue Separation Module. Includes: Luminol-S, Peroxide, Antibody Diluent 2, Anti-Rabbit Secondary Antibody, Streptavidin-HRP. |
DM-002 | Anti-Mouse Detection Module for Jess, Wes, Peggy Sue or Sally Sue Use with a Jess/Wes or Sally Sue/Peggy Sue Separation Module. Includes: Luminol-S, Peroxide, Antibody Diluent 2, Anti-Mouse Secondary Antibody, Streptavidin-HRP. |
DM-003 | No secondary Detection Module for Jess, Wes, Peggy Sue or Sally Sue Use with a Jess/Wes or Sally Sue/Peggy Sue Separation Module. Includes: Luminol-S, Peroxide, Antibody Diluent 2, Streptavidin-HRP. |
DM-004 | Biotin Detection Module for Jess, Wes, Peggy Sue or Sally Sue Use with a Jess/Wes or Sally Sue/Peggy Sue Separation Module. Includes: Secondary Streptavidin HRP, Luminol-S, Peroxide, Antibody Diluent 2, and Streptavidin-HRP (for biotinylated ladder). |
DM-005 | Anti-Human IgG Detection Module for Jess, Wes, Peggy Sue or Sally Sue Use with a Jess/Wes or Sally Sue/Peggy Sue Separation Module. Includes: Anti-Human IgG Secondary HRP Antibody, Luminol-S, Peroxide, Antibody Diluent 2, and Streptavidin-HRP. |
DM-006 | Anti-Goat Detection Module for Jess, Wes, Peggy Sue or Sally Sue Use with a Jess/Wes or Sally Sue/Peggy Sue Separation Module. Includes: Anti-Goat Secondary HRP Antibody, Luminol-S, Peroxide, Milk-free Antibody Diluent (use to dilute goat primary antibody and as blocking agent), and Streptavidin-HRP. Upon receipt, store at 2-8°C. |
DM-TP01 | Total Protein Detection Module for Jess, Wes, Peggy Sue or Sally Sue Use with a Jess/Wes or Sally Sue/Peggy Sue Separation Module. Includes: Luminol-S, Peroxide, Antibody Diluent 2, Total Protein Reconstitution Agent 2, Total Protein Streptavidin-HRP. |
SM-W001 | 12-230 kDa Jess or Wes Separation Module, 2 x 13 capillary cartridges Use with a Detection Module. Reagents for 26 data points includes two parts: Separation box with 2 Capillary Cartridges (13 capillaries per cartridge), 2 Jess/Wes 12-230 kDa Pre-filled Plates (pre-filled with Separation Matrix 2, Stacking Matrix 2, Split Running Buffer 2 and Matrix Removal Buffer), Sample Buffer, Wash Buffer (Store at RT), plus Standard Pack 1 clamshell with 2 ea. DTT, FL Standard master mix with 29 kDa System Control protein (Store at 4°C). |
SM-W002 | 12-230 kDa Jess or Wes Separation Module, 8 x 13 capillary cartridges Use with a Detection Module. Reagents for 104 data points includes two parts: Separation box with 8 Capillary Cartridges (13 capillaries per cartridge), 8 Jess/Wes 12-230 kDa Pre-filled Plates (pre-filled with Separation Matrix 2, Stacking Matrix 2, Split Running Buffer 2 and Matrix Removal Buffer), Sample Buffer, Wash Buffer (Store at RT), plus Standard Pack 1 clamshell with 8 ea. DTT, FL Standard master mix with 29 kDa System Control protein (Store at 4°C). |
SM-W003 | 12-230 kDa Jess or Wes Separation Module, 2 x 25 capillary cartridges Use with a Detection Module. Reagents for 50 data points includes two parts: Separation box with 2 Capillary Cartridges (25 capillaries per cartridge), 2 Jess/Wes 12-230 kDa Pre-filled Plates (pre-filled with Separation Matrix 2, Stacking Matrix 2, Split Running Buffer 2 and Matrix Removal Buffer), Sample Buffer, Wash Buffer (Store at RT), plus Standard Pack 1 clamshell with 2 ea. DTT, FL Standard master mix with 29 kDa System Control protein (Store at 4°C). |
SM-W004 | 12-230 kDa Jess or Wes Separation Module, 8 x 25 capillary cartridges Use with a Detection Module. Reagents for 200 data points includes two parts: Separation box with 8 Capillary Cartridges (25 capillaries per cartridge), 8 Jess/Wes 12-230 kDa Pre-filled Plates (pre-filled with Separation Matrix 2, Stacking Matrix 2, Split Running Buffer 2 and Matrix Removal Buffer), Sample Buffer, Wash Buffer (Store at RT), plus Standard Pack 1 clamshell with 8 ea. DTT, FL Standard master mix with 29 kDa System Control protein. (Store at 4°C). |
SM-W005 | 66-440 kDa Jess or Wes Separation Module, 2 x 13 capillary cartridges Use with a Detection Module. Reagents for 26 data points includes two parts: Separation box with 2 Capillary Cartridges (13 capillaries per cartridge), 2 Jess/Wes 66-440 kDa Pre-filled Plates (pre-filled with Separation Matrix 3, Stacking Matrix 2, Split Running Buffer 3 and Matrix Removal Buffer), Sample Buffer, Wash Buffer (Store at RT), plus Standard Pack 3 clamshell with 2 ea. DTT, FL Standard master mix with 90 kDa System Control protein (Store at 4°C). |
SM-W006 | 66-440 kDa Jess or Wes Separation Module, 8 x 13 capillary cartridges Use with a Detection Module. Reagents for 104 data points includes two parts: Separation box with 8 Capillary Cartridges (13 capillaries per cartridge), 8 Jess/Wes 66-440 kDa Pre-filled Plates (pre-filled with Separation Matrix 3, Stacking Matrix 2, Split Running Buffer 3 and Matrix Removal Buffer), Sample Buffer, Wash Buffer (Store at RT), plus Standard Pack 3 clamshell with 8 ea. DTT, FL Standard master mix with 90 kDa System Control protein (Store at 4°C). |
SM-W007 | 66-440 kDa Jess or Wes Separation Module, 2 x 25 capillary cartridges Use with a Detection Module. Reagents for 50 data points includes two parts: Separation box with 2 Capillary Cartridges (25 capillaries per cartridge), 2 Jess/Wes 66-440 kDa Pre-filled Plates (pre-filled with Separation Matrix 3, Stacking Matrix 2, Split Running Buffer 3 and Matrix Removal Buffer), Sample Buffer, Wash Buffer (Store at RT), plus Standard Pack 3 clamshell with 2 ea. DTT, FL Standard master mix with 90 kDa System Control protein (Store at 4°C). |
SM-W008 | 66-440 kDa Jess or Wes Separation Module, 8 x 25 capillary cartridges Use with a Detection Module. Reagents for 200 data points includes two parts: Separation box with 8 Capillary Cartridges (25 capillaries per cartridge), 8 Jess/Wes 66-440 kDa Pre-filled Plates (pre-filled with Separation Matrix 3, Stacking Matrix 2, Split Running Buffer 3 and Matrix Removal Buffer), Sample Buffer, Wash Buffer (Store at RT), plus Standard Pack 3 clamshell with 8 ea. DTT, FL Standard master mix with 90 kDa System Control protein (Store at 4°C). |
SM-W009 | 2-40 kDa Jess or Wes Separation Module, 2 x 13 capillary cartridges Requires Compass v3.0 or higher. Use with a Detection Module. Reagents for 26 data points includes two parts: Separation box with 2 Capillary Cartridges (13 capillaries per cartridge), 2 Jess/Wes 2-40 kDa Pre-filled Plates (pre-filled with Separation Matrix 2, Stacking Matrix 2, Split Running Buffer 4 and Matrix Removal Buffer), Sample Buffer, Wash Buffer (Store at RT), plus Standard Pack 5 clamshell with 2 ea. DTT, FL Standard master mix with 26 kDa System Control protein (Store at 4°C). |
SM-W010 | 2-40 kDa Jess or Wes Separation Module, 8 x 13 capillary cartridges Requires Compass v3.0 or higher. Use with a Detection Module. Reagents for 104 data points includes two parts: Separation box with 8 Capillary Cartridges (13 capillaries per cartridge), 8 Jess/Wes 2-40 kDa Pre-filled Plates (pre-filled with Separation Matrix 2, Stacking Matrix 2, Split Running Buffer 4 and Matrix Removal Buffer), Sample Buffer, Wash Buffer (Store at RT), plus Standard Pack 5 clamshell with 8 ea. DTT, FL Standard master mix with 26 kDa System Control protein (Store at 4°C). |
SM-W011 | 2-40 kDa Jess or Wes Separation Module, 2 x 25 capillary cartridges Requires Compass v3.0 or higher. Use with a Detection Module. Reagents for 50 data points includes two parts: Separation box with 2 Capillary Cartridges (25 capillaries per cartridge), 2 Jess/Wes 2-40 kDa Pre-filled Plates (pre-filled with Separation Matrix 2, Stacking Matrix 2, Split Running Buffer 4 and Matrix Removal Buffer), Sample Buffer, Wash Buffer (Store at RT), plus Standard Pack 5 clamshell with 2 ea. DTT, FL Standard master mix with 26 kDa System Control protein (Store at 4°C). |
SM-W012 | 2-40 kDa Jess or Wes Separation Module, 8 x 25 capillary cartridges Requires Compass v3.0 or higher. Use with a Detection Module. Reagents for 200 data points includes two parts: Separation box with 8 Capillary Cartridges (25 capillaries per cartridge), 8 Jess/Wes 2-40 kDa Pre-filled Plates (pre-filled with Separation Matrix 2, Stacking Matrix 2, Split Running Buffer 4 and Matrix Removal Buffer), Sample Buffer, Wash Buffer (Store at RT), plus Standard Pack 5 clamshell with 8 ea. DTT, FL Standard master mix with 26 kDa System Control protein (Store at 4°C). |
PS-T001w | |
SA-001 |
個別試薬
製品# | 品目 |
---|---|
PS-ST05EZ-8 | 8 pk, EZ Standard Pack 5 Includes 8 packets with one each of the Single Use Biotinylated Ladder (MW ladder spans 2-40 kDa) and Single Use FL Standard (26 kDa system control protein) vials. Reagents for 200 Simple Western data points. For use with Jess, Wes, Sally Sue, or Peggy Sue. |
PS-ST04EZ-8 | 8 pk, EZ Standard Pack 4 Includes 8 packets with one each of the Single Use Biotinylated Ladder (MW ladder spans 66-440 kDa) and Single Use FL Standard (200 kDa system control protein) vials. Reagents for 200 Simple Western data points. For use with Jess, Wes, Sally Sue, or Peggy Sue. |
PS-ST03EZ-8 | 8 pk, EZ Standard Pack 3 Includes 8 packets with one each of the Single Use Biotinylated Ladder (MW ladder spans 66-440 kDa) and Single Use FL Standard (90 kDa system control protein) vials. Reagents for 200 Simple Western data points. For use with Jess, Wes, Sally Sue, or Peggy Sue. |
PS-ST02EZ-8 | 8 pk, EZ Standard Pack 2 Includes 8 packets with one each of the Single Use Biotinylated Ladder (MW ladder spans 12-230 kDa) and Single Use FL Standard (180 kDa system control protein) vials. Reagents for 200 Simple Western data points. For use with Jess, Wes, Sally Sue, or Peggy Sue. |
PS-ST01EZ-8 | 8 pk, EZ Standard Pack 1 Includes 8 packets with one each of the Single Use Biotinylated Ladder (MW ladder spans 12-230 kDa) and Single Use FL Standard (29 kDa system control protein) vials. Reagents for 200 Simple Western data points. For use with Jess, Wes, Sally Sue, or Peggy Sue. |
PS-FL01-8 | Fluorescent 5x Master Mix 1 Includes 8 packets with one each of the Single Use FL Standard (29 kDa system control protein) and Single Use DTT vials. For use with Jess, Wes, Peggy Sue or Sally Sue 12-230 Separation Modules |
PS-FL03-8 | Fluorescent 5x Master Mix 3 Includes 8 packets with one each of the Single Use FL Standard (90 kDa system control protein) and Single Use DTT vials. For use with Jess, Wes, Peggy Sue or Sally Sue 66-440 kD Separation Modules |
PS-FL05-8 | Fluorescent 5x Master Mix 5 Includes 8 packets with one each of the Single Use FL Standard (26 kDa system control protein) and Single Use DTT vials. For use with Jess, Wes, Peggy Sue or Sally Sue 2-40 kD Separation Modules |
042-976 | 総タンパク質アッセイ用 ストレプトアビジン-HRP Total Protein Streptavidin-HRP Use with Compass v2.6 or higher. Streptavidin-HRP for Total Protein Assay for Jess/Wes, Sally Sue/Peggy Sue, 2.0 mL. Ready to use. |
042-414 | ストレプトアビジン-HRP Streptavidin-HRP Streptavidin-HRP Conjugate (ready-to-use reagent) for use with the Simple Western Size Standard. |
042-195 | 10X サンプルバッファ Jess, Wes, Sally Sue, Peggy Sue Sample Buffer Jess, Wes, Sally Sue, Peggy Sue 10X Sample Buffer (440 µL) |
042-206 | 抗ラビット二次抗体 Anti-Rabbit Secondary Antibody Goat Anti-Rabbit Secondary HRP Conjugate (ready-to-use reagent). For Jess, Wes, Sally Sue, and Peggy Sue only. |
042-205 | 抗マウス二次抗体 Anti-Mouse Secondary Antibody Goat Anti-Mouse Secondary HRP Conjugate (ready-to-use reagent). For Jess, Wes, Sally Sue, and Peggy Sue only. |
043-426 | 20X Anti-Rabbit HRP Conjugate 20X Anti-Rabbit HRP Conjugate, 150 µL. To be diluted to 1X with RTU Anti-Mouse Secondary Antibody (042-205) when multiplexing with primary antibodies raised in mouse and rabbit. |
042-203 | 抗体希釈溶液II 抗体希釈溶液II (20 mL) |
042-196 | 10X システムコントロール ラビット一次抗体 一次抗体と合わせて抗体希釈溶液に添加用 10X System Control Primary Antibody-Rabbit To be used with rabbit primary antibody to Antibody Diluent. Detects system controls. Match with Standard pack 1, 2, 3 or 4 (250 µl/vial) |
042-191 | 10X システムコントロール マウス一次抗体 一次抗体と合わせて抗体希釈溶液に添加用 10X System Control Primary Antibody-Mouse To be used with mouse primary antibody to Antibody Diluent. Detects system controls. Match with Standard pack 1, 2, 3 or 4 (250 µl/vial) |
042-202 | ウォッシュバッファ ウォッシュバッファ (60 mL) |
PS-CS01 | 化学発光基質 化学発光基質(2.0 mL/ボトル、2本)、Luminol-S (043-311)およびPeroxide (043-379) |
042-486 | サイズベースアッセイ用 Erk1一次抗体 Erk1 ラビット一 次抗体、1倍ストック(1 mL) Erk 1 Primary Antibody for Size Assays Erk 1 Rabbit Primary Antibody, 1X stock (1 mL) |
042-488 | サイズアッセイ用Hela細胞ライセートコントロール Hela細胞ライセート、RIPA可溶化バッファにより溶解(20 µL) HeLa Lysate Controls for Jess, Wes, Sally Sue and Peggy Sue HeLa lysate, lysed in RIPA Lysis Buffer (20 µL/vial). For use with Jess, Wes, Sally Sue, or Peggy Sue. |
043-311 | Luminol-S Jess, Wes, Peggy Sue, Sally Sue, Peggy, Sally or Simon Luminol-S (2 mL) |
043-379 | Peroxide Jess, Wes, Peggy Sue, Sally Sue, Peggy, Sally or Simon Peroxide (2 mL) |
043-522-2 | Anti-Goat Secondary HRP Antibody Donkey Anti-Goat Secondary HRP Conjugate (ready-to-use reagent). For Jess, Wes, Sally Sue, and Peggy Sue (2 x 1 mL). Use our Milk-free Antibody Diluent (043-524) to dilute goat primary and as a blocking agent. Ships at room temperature. Upon receipt, store at 2-8°C. |
043-491-2 | Anti-Human IgG Secondary HRP Antibody Goat Anti-Human Secondary HRP Conjugate (ready-to-use reagent). For Jess, Wes, Sally Sue, and Peggy Sue (2 x 1 mL). Ships at room temperature. Upon receipt, store at 2-8°C. |
043-459-2 | Secondary Streptavidin-HRP Secondary Streptavidin-HRP Conjugate (ready-to-use reagent). For Jess, Wes, Sally Sue, and Peggy Sue (2 x 1 mL). Use with a biotinylated antibody. For total protein assay use 042-976 and to detect biotinylated molecular weight ladders use 042-414. Ships with ice pack. Upon receipt, store at 2-8°C. |
043-524 | Milk-free Antibody Diluent Milk-free Antibody Diluent for Jess, Wes, Peggy Sue and Sally Sue (20 mL). We recommend its use for dilution of goat primary, anti-goat secondary and as blocking agent as it has been shown to be superior in reducing background compared to other diluents tested. Ships at room temperature. Upon receipt, store at 2-8°C. |
消耗品
製品# | 品目 |
---|---|
PS-PP05 | Jess/Wes 2-40 kDa Pre-filled Plates Requires Compass v3.0 or higher. 8 Plates (pre-filled with Separation Matrix, Stacking Matrix, Split Running Buffer and Matrix Removal Buffer). |
PS-PP04 | Jess/Wes 66-440 kDa Pre-filled Plates with Split Buffer Use with Compass v2.7 or higher. 8 Plates (pre-filled with Separation Matrix, Stacking Matrix, Split Running Buffer 3 and Matrix Removal Buffer). |
PS-PP03 | Jess/Wes 12-230 kDa Pre-filled Plates with Split Buffer Use with Compass v2.7 or higher. 8 Plates (pre-filled with Separation Matrix, Stacking Matrix, Split Running Buffer 2 and Matrix Removal Buffer). |
PS-CC01 | Jess/Wes 25キャピラリカートリッジ 8パック Jess/Wes Capillaries (8 cartridges - 25 capillaries/cartridge) |
PS-CC02 | Jess/Wes 13キャピラリカートリッジ 8パック Jess/Wes Capillaries (8 cartridges - 13 capillaries/cartridge) |