Wes 試薬と消耗品

Certified antibodies

Wes試薬と消耗品はWes専用に製造されており、Compassソフトウェアver 2.5以上と互換ファームウェアとあわせて使用してください。

Assay Modules

製品# 品目
DM-001 Anti-Rabbit Detection Module for Jess, Wes, Peggy Sue or Sally Sue
Use with a Jess/Wes or Sally Sue/Peggy Sue Separation Module. Includes: Luminol-S, Peroxide, Antibody Diluent 2, Anti-Rabbit Secondary Antibody, Streptavidin-HRP.
DM-002 Anti-Mouse Detection Module for Jess, Wes, Peggy Sue or Sally Sue
Use with a Jess/Wes or Sally Sue/Peggy Sue Separation Module. Includes: Luminol-S, Peroxide, Antibody Diluent 2, Anti-Mouse Secondary Antibody, Streptavidin-HRP.
DM-003 No secondary Detection Module for Jess, Wes, Peggy Sue or Sally Sue
Use with a Jess/Wes or Sally Sue/Peggy Sue Separation Module. Includes: Luminol-S, Peroxide, Antibody Diluent 2, Streptavidin-HRP.
DM-004 Biotin Detection Module for Jess, Wes, Peggy Sue or Sally Sue
Use with a Jess/Wes or Sally Sue/Peggy Sue Separation Module. Includes: Secondary Streptavidin HRP, Luminol-S, Peroxide, Antibody Diluent 2, and Streptavidin-HRP (for biotinylated ladder).
DM-005 Anti-Human IgG Detection Module for Jess, Wes, Peggy Sue or Sally Sue
Use with a Jess/Wes or Sally Sue/Peggy Sue Separation Module. Includes: Anti-Human IgG Secondary HRP Antibody, Luminol-S, Peroxide, Antibody Diluent 2, and Streptavidin-HRP.
DM-006 Anti-Goat Detection Module for Jess, Wes, Peggy Sue or Sally Sue
Use with a Jess/Wes or Sally Sue/Peggy Sue Separation Module. Includes: Anti-Goat Secondary HRP Antibody, Luminol-S, Peroxide, Milk-free Antibody Diluent (use to dilute goat primary antibody and as blocking agent), and Streptavidin-HRP. Upon receipt, store at 2-8°C.
DM-TP01 Total Protein Detection Module for Jess, Wes, Peggy Sue or Sally Sue
Use with a Jess/Wes or Sally Sue/Peggy Sue Separation Module. Includes: Luminol-S, Peroxide, Antibody Diluent 2, Total Protein Reconstitution Agent 2, Total Protein Streptavidin-HRP.
SM-W001 12-230 kDa Jess or Wes Separation Module, 2 x 13 capillary cartridges
Use with a Detection Module. Reagents for 26 data points includes two parts: Separation box with 2 Capillary Cartridges (13 capillaries per cartridge), 2 Jess/Wes 12-230 kDa Pre-filled Plates (pre-filled with Separation Matrix 2, Stacking Matrix 2, Split Running Buffer 2 and Matrix Removal Buffer), Sample Buffer, Wash Buffer (Store at RT), plus Standard Pack 1 clamshell with 2 ea. DTT, FL Standard master mix with 29 kDa System Control protein (Store at 4°C).
SM-W002 12-230 kDa Jess or Wes Separation Module, 8 x 13 capillary cartridges
Use with a Detection Module. Reagents for 104 data points includes two parts: Separation box with 8 Capillary Cartridges (13 capillaries per cartridge), 8 Jess/Wes 12-230 kDa Pre-filled Plates (pre-filled with Separation Matrix 2, Stacking Matrix 2, Split Running Buffer 2 and Matrix Removal Buffer), Sample Buffer, Wash Buffer (Store at RT), plus Standard Pack 1 clamshell with 8 ea. DTT, FL Standard master mix with 29 kDa System Control protein (Store at 4°C).
SM-W003 12-230 kDa Jess or Wes Separation Module, 2 x 25 capillary cartridges
Use with a Detection Module. Reagents for 50 data points includes two parts: Separation box with 2 Capillary Cartridges (25 capillaries per cartridge), 2 Jess/Wes 12-230 kDa Pre-filled Plates (pre-filled with Separation Matrix 2, Stacking Matrix 2, Split Running Buffer 2 and Matrix Removal Buffer), Sample Buffer, Wash Buffer (Store at RT), plus Standard Pack 1 clamshell with 2 ea. DTT, FL Standard master mix with 29 kDa System Control protein (Store at 4°C).
SM-W004 12-230 kDa Jess or Wes Separation Module, 8 x 25 capillary cartridges
Use with a Detection Module. Reagents for 200 data points includes two parts: Separation box with 8 Capillary Cartridges (25 capillaries per cartridge), 8 Jess/Wes 12-230 kDa Pre-filled Plates (pre-filled with Separation Matrix 2, Stacking Matrix 2, Split Running Buffer 2 and Matrix Removal Buffer), Sample Buffer, Wash Buffer (Store at RT), plus Standard Pack 1 clamshell with 8 ea. DTT, FL Standard master mix with 29 kDa System Control protein. (Store at 4°C).
SM-W005 66-440 kDa Jess or Wes Separation Module, 2 x 13 capillary cartridges
Use with a Detection Module. Reagents for 26 data points includes two parts: Separation box with 2 Capillary Cartridges (13 capillaries per cartridge), 2 Jess/Wes 66-440 kDa Pre-filled Plates (pre-filled with Separation Matrix 3, Stacking Matrix 2, Split Running Buffer 3 and Matrix Removal Buffer), Sample Buffer, Wash Buffer (Store at RT), plus Standard Pack 3 clamshell with 2 ea. DTT, FL Standard master mix with 90 kDa System Control protein (Store at 4°C).
SM-W006 66-440 kDa Jess or Wes Separation Module, 8 x 13 capillary cartridges
Use with a Detection Module. Reagents for 104 data points includes two parts: Separation box with 8 Capillary Cartridges (13 capillaries per cartridge), 8 Jess/Wes 66-440 kDa Pre-filled Plates (pre-filled with Separation Matrix 3, Stacking Matrix 2, Split Running Buffer 3 and Matrix Removal Buffer), Sample Buffer, Wash Buffer (Store at RT), plus Standard Pack 3 clamshell with 8 ea. DTT, FL Standard master mix with 90 kDa System Control protein (Store at 4°C).
SM-W007 66-440 kDa Jess or Wes Separation Module, 2 x 25 capillary cartridges
Use with a Detection Module. Reagents for 50 data points includes two parts: Separation box with 2 Capillary Cartridges (25 capillaries per cartridge), 2 Jess/Wes 66-440 kDa Pre-filled Plates (pre-filled with Separation Matrix 3, Stacking Matrix 2, Split Running Buffer 3 and Matrix Removal Buffer), Sample Buffer, Wash Buffer (Store at RT), plus Standard Pack 3 clamshell with 2 ea. DTT, FL Standard master mix with 90 kDa System Control protein (Store at 4°C).
SM-W008 66-440 kDa Jess or Wes Separation Module, 8 x 25 capillary cartridges
Use with a Detection Module. Reagents for 200 data points includes two parts: Separation box with 8 Capillary Cartridges (25 capillaries per cartridge), 8 Jess/Wes 66-440 kDa Pre-filled Plates (pre-filled with Separation Matrix 3, Stacking Matrix 2, Split Running Buffer 3 and Matrix Removal Buffer), Sample Buffer, Wash Buffer (Store at RT), plus Standard Pack 3 clamshell with 8 ea. DTT, FL Standard master mix with 90 kDa System Control protein (Store at 4°C).
SM-W009 2-40 kDa Jess or Wes Separation Module, 2 x 13 capillary cartridges
Requires Compass v3.0 or higher. Use with a Detection Module. Reagents for 26 data points includes two parts: Separation box with 2 Capillary Cartridges (13 capillaries per cartridge), 2 Jess/Wes 2-40 kDa Pre-filled Plates (pre-filled with Separation Matrix 2, Stacking Matrix 2, Split Running Buffer 4 and Matrix Removal Buffer), Sample Buffer, Wash Buffer (Store at RT), plus Standard Pack 5 clamshell with 2 ea. DTT, FL Standard master mix with 26 kDa System Control protein (Store at 4°C).
SM-W010 2-40 kDa Jess or Wes Separation Module, 8 x 13 capillary cartridges
Requires Compass v3.0 or higher. Use with a Detection Module. Reagents for 104 data points includes two parts: Separation box with 8 Capillary Cartridges (13 capillaries per cartridge), 8 Jess/Wes 2-40 kDa Pre-filled Plates (pre-filled with Separation Matrix 2, Stacking Matrix 2, Split Running Buffer 4 and Matrix Removal Buffer), Sample Buffer, Wash Buffer (Store at RT), plus Standard Pack 5 clamshell with 8 ea. DTT, FL Standard master mix with 26 kDa System Control protein (Store at 4°C).
SM-W011 2-40 kDa Jess or Wes Separation Module, 2 x 25 capillary cartridges
Requires Compass v3.0 or higher. Use with a Detection Module. Reagents for 50 data points includes two parts: Separation box with 2 Capillary Cartridges (25 capillaries per cartridge), 2 Jess/Wes 2-40 kDa Pre-filled Plates (pre-filled with Separation Matrix 2, Stacking Matrix 2, Split Running Buffer 4 and Matrix Removal Buffer), Sample Buffer, Wash Buffer (Store at RT), plus Standard Pack 5 clamshell with 2 ea. DTT, FL Standard master mix with 26 kDa System Control protein (Store at 4°C).
SM-W012 2-40 kDa Jess or Wes Separation Module, 8 x 25 capillary cartridges
Requires Compass v3.0 or higher. Use with a Detection Module. Reagents for 200 data points includes two parts: Separation box with 8 Capillary Cartridges (25 capillaries per cartridge), 8 Jess/Wes 2-40 kDa Pre-filled Plates (pre-filled with Separation Matrix 2, Stacking Matrix 2, Split Running Buffer 4 and Matrix Removal Buffer), Sample Buffer, Wash Buffer (Store at RT), plus Standard Pack 5 clamshell with 8 ea. DTT, FL Standard master mix with 26 kDa System Control protein (Store at 4°C).
PS-T001a
RP-001
SA-001

個別試薬

製品# 品目
PS-ST01EZ-8 8 pk, EZ Standard Pack 1
Includes 8 packets with one each of the Single Use Biotinylated Ladder (MW ladder spans 12-230 kDa) and Single Use FL Standard (29 kDa system control protein) vials. Reagents for 200 Simple Western data points. For use with Jess, Wes, Sally Sue, or Peggy Sue.
PS-ST02EZ-8 8 pk, EZ Standard Pack 2
Includes 8 packets with one each of the Single Use Biotinylated Ladder (MW ladder spans 12-230 kDa) and Single Use FL Standard (180 kDa system control protein) vials. Reagents for 200 Simple Western data points. For use with Jess, Wes, Sally Sue, or Peggy Sue.
PS-ST03EZ-8 8 pk, EZ Standard Pack 3
Includes 8 packets with one each of the Single Use Biotinylated Ladder (MW ladder spans 66-440 kDa) and Single Use FL Standard (90 kDa system control protein) vials. Reagents for 200 Simple Western data points. For use with Jess, Wes, Sally Sue, or Peggy Sue.
PS-ST04EZ-8 8 pk, EZ Standard Pack 4
Includes 8 packets with one each of the Single Use Biotinylated Ladder (MW ladder spans 66-440 kDa) and Single Use FL Standard (200 kDa system control protein) vials. Reagents for 200 Simple Western data points. For use with Jess, Wes, Sally Sue, or Peggy Sue.
PS-ST05EZ-8 8 pk, EZ Standard Pack 5
Includes 8 packets with one each of the Single Use Biotinylated Ladder (MW ladder spans 2-40 kDa) and Single Use FL Standard (26 kDa system control protein) vials. Reagents for 200 Simple Western data points. For use with Jess, Wes, Sally Sue, or Peggy Sue.
PS-FL01-8 Fluorescent 5x Master Mix 1
Includes 8 packets with one each of the Single Use FL Standard (29 kDa system control protein) and Single Use DTT vials. For use with Jess, Wes, Peggy Sue or Sally Sue 12-230 Separation Modules
PS-FL03-8 Fluorescent 5x Master Mix 3
Includes 8 packets with one each of the Single Use FL Standard (90 kDa system control protein) and Single Use DTT vials. For use with Jess, Wes, Peggy Sue or Sally Sue 66-440 kD Separation Modules
PS-FL05-8 Fluorescent 5x Master Mix 5
Includes 8 packets with one each of the Single Use FL Standard (26 kDa system control protein) and Single Use DTT vials. For use with Jess, Wes, Peggy Sue or Sally Sue 2-40 kD Separation Modules
042-976 総タンパク質アッセイ用 ストレプトアビジン-HRP
Total Protein Streptavidin-HRP
Use with Compass v2.6 or higher. Streptavidin-HRP for Total Protein Assay for Jess/Wes, Sally Sue/Peggy Sue, 2.0 mL. Ready to use.
042-414 ストレプトアビジン-HRP
Streptavidin-HRP
Streptavidin-HRP Conjugate (ready-to-use reagent) for use with the Simple Western Size Standard.
042-488 サイズアッセイ用Hela細胞ライセートコントロール
Hela細胞ライセート、RIPA可溶化バッファにより溶解(20 µL)
HeLa Lysate Controls for Jess, Wes, Sally Sue and Peggy Sue
HeLa lysate, lysed in RIPA Lysis Buffer (20 µL/vial). For use with Jess, Wes, Sally Sue, or Peggy Sue.
042-195 10X サンプルバッファ
Jess, Wes, Sally Sue, Peggy Sue Sample Buffer
Jess, Wes, Sally Sue, Peggy Sue 10X Sample Buffer (440 µL)
042-206 抗ラビット二次抗体
Anti-Rabbit Secondary Antibody
Goat Anti-Rabbit Secondary HRP Conjugate (ready-to-use reagent). For Jess, Wes, Sally Sue, and Peggy Sue only.
042-205 抗マウス二次抗体
Anti-Mouse Secondary Antibody
Goat Anti-Mouse Secondary HRP Conjugate (ready-to-use reagent). For Jess, Wes, Sally Sue, and Peggy Sue only.
043-426 20X Anti-Rabbit HRP Conjugate
20X Anti-Rabbit HRP Conjugate, 150 µL. To be diluted to 1X with RTU Anti-Mouse Secondary Antibody (042-205) when multiplexing with primary antibodies raised in mouse and rabbit.
043-522-2 Anti-Goat Secondary HRP Antibody
Donkey Anti-Goat Secondary HRP Conjugate (ready-to-use reagent). For Jess, Wes, Sally Sue, and Peggy Sue (2 x 1 mL). Use our Milk-free Antibody Diluent (043-524) to dilute goat primary and as a blocking agent. Ships at room temperature. Upon receipt, store at 2-8°C.
043-491-2 Anti-Human IgG Secondary HRP Antibody
Goat Anti-Human Secondary HRP Conjugate (ready-to-use reagent). For Jess, Wes, Sally Sue, and Peggy Sue (2 x 1 mL). Ships at room temperature. Upon receipt, store at 2-8°C.
043-459-2 Secondary Streptavidin-HRP
Secondary Streptavidin-HRP Conjugate (ready-to-use reagent). For Jess, Wes, Sally Sue, and Peggy Sue (2 x 1 mL). Use with a biotinylated antibody. For total protein assay use 042-976 and to detect biotinylated molecular weight ladders use 042-414. Ships with ice pack. Upon receipt, store at 2-8°C.
042-486 サイズベースアッセイ用 Erk1一次抗体
Erk1 ラビット一 次抗体、1倍ストック(1 mL)
Erk 1 Primary Antibody for Size Assays
Erk 1 Rabbit Primary Antibody, 1X stock (1 mL)
042-203 抗体希釈溶液II
抗体希釈溶液II (20 mL)
043-524 Milk-free Antibody Diluent
Milk-free Antibody Diluent for Jess, Wes, Peggy Sue and Sally Sue (20 mL). We recommend its use for dilution of goat primary, anti-goat secondary and as blocking agent as it has been shown to be superior in reducing background compared to other diluents tested. Ships at room temperature. Upon receipt, store at 2-8°C.
042-196 10X システムコントロール ラビット一次抗体
一次抗体と合わせて抗体希釈溶液に添加用
10X System Control Primary Antibody-Rabbit
To be used with rabbit primary antibody to Antibody Diluent. Detects system controls. Match with Standard pack 1, 2, 3 or 4 (250 µl/vial)
042-191 10X システムコントロール マウス一次抗体
一次抗体と合わせて抗体希釈溶液に添加用
10X System Control Primary Antibody-Mouse
To be used with mouse primary antibody to Antibody Diluent. Detects system controls. Match with Standard pack 1, 2, 3 or 4 (250 µl/vial)
042-202 ウォッシュバッファ
ウォッシュバッファ (60 mL)
PS-CS01 化学発光基質
化学発光基質(2.0 mL/ボトル、2本)、Luminol-S (043-311)およびPeroxide (043-379)
043-311 Luminol-S
Jess, Wes, Peggy Sue, Sally Sue, Peggy, Sally or Simon Luminol-S (2 mL)
043-379 Peroxide
Jess, Wes, Peggy Sue, Sally Sue, Peggy, Sally or Simon Peroxide (2 mL)

消耗品

製品# 品目
PS-PP05 Jess/Wes 2-40 kDa Pre-filled Plates
Requires Compass v3.0 or higher. 8 Plates (pre-filled with Separation Matrix, Stacking Matrix, Split Running Buffer and Matrix Removal Buffer).
PS-PP04 Jess/Wes 66-440 kDa Pre-filled Plates with Split Buffer
Use with Compass v2.7 or higher. 8 Plates (pre-filled with Separation Matrix, Stacking Matrix, Split Running Buffer 3 and Matrix Removal Buffer).
PS-PP03 Jess/Wes 12-230 kDa Pre-filled Plates with Split Buffer
Use with Compass v2.7 or higher. 8 Plates (pre-filled with Separation Matrix, Stacking Matrix, Split Running Buffer 2 and Matrix Removal Buffer).
PS-CC01 Jess/Wes 25キャピラリカートリッジ 8パック
Jess/Wes Capillaries (8 cartridges - 25 capillaries/cartridge)
PS-CC02 Jess/Wes 13キャピラリカートリッジ 8パック
Jess/Wes Capillaries (8 cartridges - 13 capillaries/cartridge)