Maurice C. 試薬と消耗品

モーリスC.試薬および消耗品は、モーリスとモーリスC.システムでの使用のために設計されており、Compass for iCEソフトウェア バージョン1.0と組み合わせて使用する必要があります。

cIEF Kits

Part # Description
PS-MDK01-C Maurice cIEF Method Development Kit
The cIEF Method Development Kit provides all the reagents and instructions to help you develop fast and robust cIEF method on Maurice and Maurice C. systems. The kit includes a Method Development Guide as well as a selection of reagents required for cIEF method development on the system. This kit includes a Fluorescence Calibration Standard, System Suitability Kit, Anolyte, Catholyte, Methyl Cellulose, five types of Ampholytes (Pharmalyte pH ranges 3-10, 2.5-5, 5-8 and 8 to 10.5 and Servalyte pH range 2-9), eight pI Markers (3.38, 4.05, 5.85, 6.14, 7.05, 8.40, 9.99 and 10.17) and additives (lyophilized urea and arginine). 30 Samples/kit. The expiration date for this kit is 12 months from date of manufacture.
For use with the cIEF cartridge (PS-MC02-C) on Maurice and Maurice C. systems only.
046-036 Maurice cIEF Chemical Test Kit
The cIEF Chemical Test Kit is designed to confirm the overall performance of the Maurice and Maurice C. systems with the cIEF cartridge (PS-MC02-C) on 8 separate occasions. The kit contains Anolyte, Catholyte, Methyl Cellulose, Fluorescence Calibration Standard and a System Suitabilty kit. Each time, the performance can be checked up to 24 hours. The expiration date for this kit is 12 months from date of manufacture. 8 runs/kit.
For use with the cIEF cartridge (PS-MC02-C) on Maurice and Maurice C. systems only.
046-044 Maurice cIEF System Suitability Kit
"The cIEF System Suitability Kit is used to run a control test for cIEF application on Maurice and Maurice C. systems on 8 separate occasions. Each time, the performance can be checked up to 24 hours. The kit contains a vial of lyophilized Peptide Panel and a vial of System Suitability Test mix. 8 runs/kit. The expiration date for this kit is 12 months from date of manufacture.
For use with the cIEF cartridge (PS-MC02-C) on Maurice and Maurice C. systems only.
102506 iCE Electrolyte Kit
These 100 mL Anolyte and Catholyte solutions in 0.1% MC are used to fill the electrolyte tanks in Maurice cIEF cartridge as well as FC and HT cartridges. The labels and bottles are color coded to improve safety. The kit contains 2 x 100 mL bottles. The expiration date for this kit is 12 months from date of manufacture.
For use with Maurice, Maurice C., iCE3, and iCE280 systems only.

Individual Reagents

Part # Description
102505 0.5% Methyl Cellulose Solution
0.5% Methyl Cellulose Solution, 100 mL. Use this concentration for the wash cycle between injections. The solution is filtered to ensure consistent viscosity to coat the capillary lumen to minimize electroosmotic flow (EOF). Conveniently packaged in 2 x 100 mL bottles. The expiration date for this kit is 12 months from date of manufacture.
For use with Maurice, Maurice C., iCE3, and iCE280 systems only.
101876 1% Methyl Cellulose Solution
1% Methyl Cellulose Solution, 100 mL. This solution is used to prepare samples for the cIEF applications. The expiration date for this kit is 12 months from date of manufacture.
For use with Maurice, Maurice C., iCE3, and iCE280 systems only.
046-025 Maurice cIEF Fluorescence Calibration Standard
Fluorescence Calibration Standard for cIEF application. 5.5 mL.
For use with Maurice and Maurice C. systems only.
046-575 SimpleSol Protein Solubilizer for cIEF
SimpleSol Protein Solubilizer, 200 mL.
For use with Maurice, Maurice C. and iCE3 systems.
046-028 Maurice cIEF pI Marker - 3.38
210 µL, Lyophilized
046-029 Maurice cIEF pI Marker - 4.05
210 µL, Lyophilized
046-030 Maurice cIEF pI Marker - 5.85
210 µL, Lyophilized
046-031 Maurice cIEF pI Marker - 6.14
210 µL, Lyophilized
046-032 Maurice cIEF pI Marker - 7.05
210 µL, Lyophilized
046-033 Maurice cIEF pI Marker - 8.40
210 µL, Lyophilized
046-047 Maurice cIEF pI Marker - 9.50
210 µL, Lyophilized
046-034 Maurice cIEF pI Marker - 9.99
210 µL, Lyophilized
046-035 Maurice cIEF pI Marker - 10.17
210 µL, Lyophilized
042-691 Maurice cIEF 500 mM Arginine
500 µL

Consumables

Part # Description
PS-MC02-C Maurice cIEF Cartridges
Cartridge for cIEF application, 2 Cartridges/Pk.
For use with Maurice (090-000) and Maurice C. (090-002) systems only.
046-123 Maurice cIEF Electrolyte Tank Caps
Electrolyte tank caps, 20 mm. Red is used for Anolyte tank and the Grey cap is used for the Catholyte tank. 5 pairs/pk
101788 Electrolyte Pipette
Pipettes with soft tips for adding anolyte and catholyte into the electrolyte tanks in the cIEF cartridge. 10/pk
046-017 Maurice Glass Reagent Vials, 2 mL
Screw-top glass vials, 2 mL. 100/pk.
For use with Maurice, Maurice S., and Maurice C. systems only.
046-083 Maurice Sample Vials with Integrated inserts, 0.2 mL
Vials with integrated inserts for samples, accomodates 200 µL sample volume. 100/pk.
For use with Maurice, Maurice S., and Maurice C. systems only.
046-573 Maurice cIEF Blue Pressure Caps
Pressure screw tops with O-ring for glass vials (046-017), 12/pk.
For use with cIEF application only.
046-138 Maurice Clear Screw Caps
Clear screw caps with round opening, 100/pk.
For use with Maurice, Maurice S., and Maurice C. systems only.
046-021 Maurice 96-Well plates
96-well plate for high-throughput analysis, 10/pk.
For use with Maurice, Maurice S., and Maurice C. systems only.
046-379 Onboard mixing vials 6 mL Maurice cIEF
12 x 6 mL Bottle for Maurice-OBM and Maurice C. OBM